summaryrefslogtreecommitdiffhomepage
AgeCommit message (Collapse)Author
2012-08-29cleaned up imports, renamed variableReto Habluetzel
2012-08-29added dynnetwork, which selects the busiest network of a list and displays itReto Habluetzel
2012-08-29News and credits for the new dock mode supportJose Antonio Ortega Ruiz
2012-08-29Add '-d' for dockapp modeArnout
This makes xmobar work in windowmanagers that support _NET_WM_WINDOW_TYPE_DOCK but not _NET_WM_STRUT, such as Notion
2012-08-27description for PipeReader2Reto Habluetzel
2012-08-27added PipeReader2 which accepts a defaultReto Habluetzel
2012-08-22Merge remote-tracking branch 'jrk/dbusstuff' into jrkJose Antonio Ortega Ruiz
2012-08-22Merge remote-tracking branch 'jrk/replacemvar' into jrkJose Antonio Ortega Ruiz
Conflicts: readme.md
2012-08-22Configuration example for XMonad using the DBus interfaceJochen Keil
Mainly code from my config which does the following: When I press my modifier key (which is xK_Alt_L) then xmobar appears. When I keep the key pressed for longer than 400ms (which is often the when tabbing through windows, changing workspaces, etc), then upon release xmobar will be hidden immediately. If I press xK_Alt_L for less than 400ms (very briefly), then xmobar pops up, and will automatically disappear after 2 seconds.
2012-08-22Make it possible to delay Hide, Reveal and Toggle signalsJochen Keil
Previously Hide, Reveal and Toggle were immediate actions. This is the same behaviour as if called now with 0 as parameter. If the parameter is a positive non zero value it is taken as a delay for the requested action. After the delay (implemented using threadDelay) a new signal is sent with zero with no timeout being effective immediately. This is necessary to evaluate the persistency flag after the delay because it might have changed in the meantime. Effectively this means that it is possible to cancel the delayed operation by calling TogglePersistent.
2012-08-22Refactor MVar SignalType to TMVar SignalTypeJochen Keil
Replace MVar with TMVar from the STM package. This is common for ghc now. Since STM is used everywhere else in the src it also adds no additional dependencies. The main reason for this switch is, that readMVar, swapMVar, etc. are only atomically if there is no other producer for this MVar i.e. putMVar. For example readMVar is a combination of putMVar and takeMVar. Due to scheduling and readMVar's non-atomicity it is possible that values written to the MVar appear in the wrong order. Using TMVar fixes this problem, since it allows really atomical read/swap operations.
2012-08-22Allow multiple signals over dbus at onceJochen Keil
It's easy to implement, since arguments to dbus method calls are handed over as list anyway. It also removes the need for safeHead. Bottom line: extra functionality without extra cost.
2012-08-19Doc tweakJose Antonio Ortega Ruiz
2012-08-19Improving the documentation of monitor argsJose Antonio Ortega Ruiz
Following the discussion of pull request #59 in github.
2012-08-19Improving the documentation of monitor argsJose Antonio Ortega Ruiz
Following the discussion of pull request #59 in github.
2012-08-16Update src/Signal.hssoul9
Fix build failure: safeHead is needed even when dbus isn't.
2012-08-16Merging github pull request 57Jose Antonio Ortega Ruiz
Conflicts: readme.md
2012-08-16Documentation bit for 'lowerOnStart' optionJochen Keil
2012-08-16New configuration option 'hideOnStart'Jochen Keil
When set to True the window is initially not mapped, i.e. hidden. It then can be toggled manually (for example using the dbus interface) or automatically (by a plugin) to make it reappear (unhide/reveal).
2012-08-14Bugfix: Replace the TMVar String with a TVar (Maybe String)Jochen Keil
The problem was a race condition which occured when running multiple threads with a small timeout value. Then the TMVar could be left empty. (e.g. hitting a key which causes an operation to write to the pipe very fast) This meant that tryTakeTMVar would return Nothing which would cause all subsequent reset threads to not call cb and keep a stale string on display. By using a Maybe String wrapped in a TVar there is always a valid value available which can be used to restore the display (or not if it's Nothing, but that's desired then and not because another thread was scheduled earlier).
2012-08-13Documentation updatesJose Antonio Ortega Ruiz
2012-08-13LICENSE -> licenseJose Antonio Ortega Ruiz
2012-08-13with_dbus documentedJose Antonio Ortega Ruiz
2012-08-13TypoJose Antonio Ortega Ruiz
2012-08-13Merge for pull request #53Jose Antonio Ortega Ruiz
2012-08-13New goodies by Jochen spelled out in NEWSJose Antonio Ortega Ruiz
2012-08-13Jochen in the list of contributorsJose Antonio Ortega Ruiz
2012-08-13Missing file headers and lintingJose Antonio Ortega Ruiz
2012-08-13Missing import for 'when'Jose Antonio Ortega Ruiz
2012-08-13sh is not linked to bash on all systemsJochen Keil
This is a bash script, so for correctness is needs to be /bin/bash
2012-08-13Add a bit about DBus to documentationJochen Keil
Only one process can export the dbus interface at a time.
2012-08-13Revert lowerOnStart to its original behaviourJochen Keil
I misunderstood the intention of lowerOnStart and changed the implementation to what I thought it would have to do. This was wrong indeed, so back to original behaviour.
2012-08-12Fancier status script sampleJochen Keil
This sample script uses colors and unicode signs for drawing a status bar for e.g. volume. The unicode character can be simply changed to an ascii one in case of problems.
2012-08-12Run the DBus/IPC handler only once on program startJochen Keil
The startCommand function is called for every configured plugin. This results in multiple calls to runIPC. This it not necessary however. startLoop is a much more appropriate place, since the other signal handler (checker and eventer) are run here to.
2012-08-12Catch error when DBus connection failsJochen Keil
connectSession throws a ClientError Exception when DBUS_SESSION_BUS_ADDRESS is unset. Without exception handler this will result in program termination. Since the DBus handler merely sends a signal to the event loop it does no harm when it won't run. Normal operation will continue just if compiled without dbus support.
2012-08-12Add IPC with DBus as optional build dependencyJochen Keil
Not everybody has/wants the DBus library so this can be chosen at compile time.
2012-08-12A bit of documentation re mprisJose Antonio Ortega Ruiz
2012-08-12Fix the MPRIS plugin to work with DBus >= 0.10Jochen Keil
This commit updates the mpris plugin to use the DBus 0.10 interface. DBus-Core does no longer exist and is deprecated. DBus 0.10 does not use proxies anymore. The dependency on Data.Text also disappeared. Since I do not have/use mpris I cannot test if this works. It should however, since the functionality was just transformed to use the new interface.
2012-08-11A bit of documentation re mprisJose Antonio Ortega Ruiz
2012-08-11Documentation for the BufferedPipeReader plugin (+ sample script)Jochen Keil
The sample script is quite generic. It works for demo purposes and can be used as a template for users to write their own scripts.
2012-08-11Documentation for the DBus InterfaceJochen Keil
2012-08-11Add sample option for persistent and update option descriptionJochen Keil
Description for lowerOnStart was missing.
2012-08-11Fix the MPRIS plugin to work with DBus >= 0.10Jochen Keil
This commit updates the mpris plugin to use the DBus 0.10 interface. DBus-Core does no longer exist and is deprecated. DBus 0.10 does not use proxies anymore. The dependency on Data.Text also disappeared. Since I do not have/use mpris I cannot test if this works. It should however, since the functionality was just transformed to use the new interface.
2012-08-10Run the DBus event handler in startCommandJochen Keil
Actually run this stuff
2012-08-10Move the IsVariant SignalType instance to Signal moduleJochen Keil
This belongs here, otherwise ghc will complain about orphaned instances
2012-08-10Move safeHead to Plugins.UtilsJochen Keil
safeHead is a very general utility function with suits better into a common Util module.
2012-08-10Add an initial (working) version of the DBus IPC moduleJochen Keil
2012-08-10Add IPC with DBus as optional build dependencyJochen Keil
Not everybody has/wants the DBus library so this can be chosen at compile time.
2012-08-10New SignalType TogglePersistentJochen Keil
By sending a TogglePersistent signal the configuration option "persistent" can be changed. Thus it is possible to hide or show xmobar constantly.
2012-08-10New configuration option "persistent"Jochen Keil
When persistent is set to True then xmobar will always be mapped (revealed) and never be hidden. The flag is checked in eventLoop and operation to map/unmap windows is not carried out if persistence is desired.