summaryrefslogtreecommitdiffhomepage
path: root/src/Xmobar/Plugins/Monitors
AgeCommit message (Collapse)Author
2021-10-08try to add build action for freebsd + uptime plugin splitMichal Zielonka
2021-10-08try to reorganize modules per osMichal Zielonka
We should make better split os specify code for FreeBSD and Linux. Idea comes from @liskin.
2021-10-07add support swap info for freebsdMichal Zielonka
in freebsd swap info is available by sysctl
2021-10-07Add freebsd support for net monitor plugin.Michal Zielonka
In freebsd /sys/class/net is absent so we should use sysctl for obtaining info about stats of network. For parsing if_data struct we could use a "Foreign.Storable"
2021-10-04add reading memory specific for freebsdMichal Zielonka
In freebsd /proc/memoryinfo is absent so we should use sysctl for obtaining info about stats of memory.
2021-08-08fix: padString should not make strings longerLeo Zhang
2021-05-19Remove unused import; apply lint hintSam Kirby
2021-05-19Add k10temp pluginSam Kirby
The existing support for the coretemp kernel driver only works with Intel CPUs. This commit extends support for temperature monitoring to AMD CPUs. k10temp is a kernel driver for monitoring the temperature of AMD processors. It supports everything from AMD's 10h (Opteron/Athlon) family of processors to the latest 19h (Zen 3) family. Reference: https://www.kernel.org/doc/html/latest/hwmon/k10temp.html The meaning of the various temperatures made available has changed over the years and only `Tctl` is available on processors prior to the 17h family. Labels for these temperatures are present but as Tctl and Tdie do not contain a number I could not find a way to use these as `checkedDataRetrieval` expects an integer label. It is a PCI device and so an address needs to be supplied as part of the configuration. Example configuration: `Run K10Temp "0000:00:18.3" ["--template", "T: <Tdie>C | <Tccd1>C"] 60`
2021-03-30Add FreeBSD support to Cpu pluginKevin Zheng
2020-08-08Mpris2: accepting Word32 as type for trackNumberjao
spotifyd is funky that way
2020-08-08Fix: don't go below zero in indexed barsjao
2020-08-07removed default arg of channel', channel (Plugins.Monitors.Volume)Keith
Both functions had a default parameter for use in some error cases. Now each accepts only one parameter (a PerChannel), and return Nothing on an error. The definition of 'channel' confused me, so I simplified it. Hopefully it's now more clear that it just applies 'toInteger' to the 'IO (Maybe CLong)' that 'channel'' returns.
2020-08-07Redundant imports (mostly <$>) removedjao
2020-08-07String index as progress barjao
2020-06-23Fix hlint warningsSibi Prabakaran
2020-06-23Update based on feedback on the PRSibi Prabakaran
2020-06-23Hlint fixesSibi Prabakaran
2020-06-23Some formatting of codeSibi Prabakaran
2020-06-23More cleanupSibi Prabakaran
2020-06-23Cleanup and add some testsSibi Prabakaran
2020-06-23Fix warningsSibi Prabakaran
2020-06-23Further optimizationSibi Prabakaran
2020-06-23More efficient formattingSibi Prabakaran
2020-06-23Optimize CPU monitorSibi Prabakaran
2020-06-23Add some optimizationSibi Prabakaran
2020-06-13Look up only the first coretemp.N/hwmon dir in MultiCoreTempjao
2020-06-13Version bump, changelog, readmejao
2020-06-13Detection of Tdie and Tctl for Ryzen temperaturesjao
2020-06-13Initial support for benchmarks of the pluginsSibi Prabakaran
2020-06-12Update UVWeather branchSibi Prabakaran
2020-06-12Optimize weather plugin by reusing manager and other refactorsSibi Prabakaran
As documented in the http-client library, calling newManager is an expensive operation: ``` Creating a new Manager is a relatively expensive operation, you are advised to share a single Manager between requests instead. ``` But inspite of the haddocks in xmobar claiming that once 'Manager' is created, it will be used throughout the monitor is not true. Because for every call of `startWeather` a new manager is being created. Also I removed the option in WeatherOpts because even if it is false, it will be ultimately created in `getData` function. Also without using a manager - the plugin won't really work. So, I don't think there is any reason for this option to exist. I have introduced a new dependency http-client-tls to use the shared global manager so that we reuse the same manager every time. This simplifies a lot of code. Note that this is not really a new dependency because http-conduit already depends on it transitively.
2020-05-06recursively hlintingjao
2020-05-06hlintingjao
2020-04-21Whitespacejao
2020-04-21MPD: catch errors earlier so that reconnections are allowedjao
2020-03-05Network: up indicatorjao
2020-03-05Wireless: fix hlint warnings, reenable CI checksPaul Fertser
This makes the code hlint-clean for --cpp-define=USE_NL80211, --cpp-define=IWLIB and without --cpp-define too.
2020-02-26hlint nitjao
2020-02-25Wireless: support NL80211 userspace <-> kernelspace APIPaul Fertser
NL80211 was introduced in Linux 2.6.24 in 2007 as a new extensible universal API, replacing "wireless extensions" ioctls. It works on top of netlink, and allows direct communication to cfg80211 kernel subsystem. Since then it became a hard requirement for all upstream wireless drivers to hook into cfg80211 (SoftMAC drivers do it via the common mac80211 layer). There's still additional compatibility code that allows limited Wext functionality for cfg80211 drivers but it's buggy and can be disabled altogether when CONFIG_CFG80211_WEXT is not set. This patch makes use of "netlink" Haskell library which doesn't have any additional runtime dependencies (so neither iwlib nor libnl are required). The operation is the same as performed by "iw dev <devname> link" command. The signal level is transformed to "quality" by first clamping it to [-110; -40], then adding 110 and dividing by 70 (same meaningless formula as used by the cfg80211 Wext compatibility layer). "essid" template argument is replaced by more appropriate "ssid" (with the old variant still available for backwards compatibility)
2020-02-22Refactor code from tenthSeconds to doEveryTenthSecondsTomas Janousek
A preparation for timer coalescing: tenthSeconds is just a sleep whereas doEveryTenthSeconds enables using a central timer and waiting for all monitors to update before refreshing the window. This commit is just a simple refactor, the actual timer coalescing code comes later.
2020-02-11Battery: fix time calculations on some Linux systemsPaul Fertser
The calculations are based on the assumption that current_now (or power_now) are always positive. However, power_supply documentation in the kernel sources say nothing about it, and so some drivers provide a signed value (e.g. bq27xxx_battery_current). Discovered and fixed on ac100/paz00 netbook.
2020-02-05Update changelog and readmeslotThe
2020-02-05'Manager' is now internal to UVMeterslotThe
2020-02-05'Manager' is now internal to weatherslotThe
2020-02-05New function `getArgvs` to get all values from user inputslotThe
2020-01-27Revert "Use a single Manager across the whole application"jao
This reverts commit 1f1f0bd8b811740c84215f9ed4fa5ebd8309a990.
2020-01-27Revert "Only require http-conduit when absolutely necessary"jao
This reverts commit efb6d6817c092fe08e9b0f1b8a17bddd29d97cdb.
2020-01-16Only require http-conduit when absolutely necessaryslotThe
2020-01-16Use a single Manager across the whole applicationslotThe
2020-01-09Remove remaining redundant functions and use generic parseOptsWith insteadslotThe